FAQ
- M051 Base Series(95)
- M0518 Series(97)
- M0519 Series(43)
- M0564 Series(1)
- Mini51 Base Series(90)
- Nano100/102 Base Series(101)
- Nano103 Base Series(10)
- Nano110/112 LCD Series(100)
- Nano120 USB Series(111)
- Nano130 Advanced Series(110)
- NUC029 Series(94)
- NUC100/200 Advanced Series(102)
- NUC120/122/123/220 USB Series(116)
- NUC121/125 Series(1)
- NUC126 USB Series(2)
- NUC130/230 CAN Series(103)
- NUC131/NUC1311 CAN Series(98)
- NUC140/240 Connectivity Series(114)
- M451 Base Series(118)
- M451M Series(117)
- M452 USB Series(130)
- M4521 USB Series(1)
- M453 CAN Series(128)
- M463 CAN FD/USB HS Series(1)
- M467 Ethernet/Crypto Series(1)
- M471 Series(1)
- M479 Motor Control Series(1)
- M481 Base Series(4)
- M482 USB FS OTG Series(4)
- M483 CAN Series(4)
- M484 USB HS OTG Series(4)
- M485 Crypto Series(4)
- M487 Ethernet Series(4)
- M4TK Touch Key Series(25)
- NUC442/472 Series(130)
- NUC472 Series(1)
- NUC505 Series(138)
FAQ
How to estimate the total ADC conversion time? Issue Date:2020-04-13
The total ADC conversion time follows the equation below:
TADC = TSMP + Tconv
Where
TADC = total conversion time
TSMP = sampling time
Tconv = conversion time = 1.625us
The sampling time follows the equation below:
where FADCAQT= Fsys
With the condition Fsys = 16MHz,
The ADC controller supports continuous conversion mode and interrupt conversion mode, and the specific calculation formula is detailed below.
1. Continuous conversion mode
The total ADC conversion time is
Thus, the ADC conversion rate is 500 kHz.
2. Interrupt conversion mode
Setting ADC converting software start trigger bit and waiting for ADC flag to be set requires about 9 cycles, as shown in the figure below.
The total ADC conversion time is
Thus, the ADC conversion rate is 390 kHz.