如何計算完成一次ADC轉換所需要的時間? 日期:2020-04-13
ADC完整的轉換時間為取樣時間與轉換時間的和,計算公式如下所示:
TADC = TSMP + Tconv
其中Tconv = 1.625us 且取樣時間的計算公式如下所示:
,且 FADCAQT= Fsys
由上式可得知,在 Fsys = 16MHz 的條件下:
由於ADC轉換可設定為連續取樣模式或中斷模式,下面分別詳述轉換時間的計算方式:
1. 連續取樣模式
通過計算可以得出ADC 轉換率為500 ksps。
2. 中斷模式
需加上ADC軟啟動與等待ADC flag舉起的時間,以下圖為例約為9個指令週期時間
故
通過計算可以得出ADC 轉換率為390 ksps。